# nm-spectrum-monitor ## RF Front End Diagram (Interconnecting cables not shown) +--------------------------------------------+ |Electro-Metrics EM-6857 (Antenna) | +--------------------------------------------+ | | +--------------------------------------------+ |FRONT END | +--------------------------------------------+ |Dynatech Microwave M4-413K201L (SP4T Switch)| +--------------------------------------------+ |Mini-Circuits PMA3-14LN+ (LNA) | +--------------------------------------------+ |Mini-Circuits PMA3-14LN+ (LNA) | +--------------------------------------------+ |Dynatech Microwave M4-413K201L (SP4T Switch)| +--------------------------------------------+ | | +--------------------------------------------+ |75 ft Andrews LDF1-50 (Heliax) | +--------------------------------------------+ | | +--------------------------------------------+ |BASE | +--------------------------------------------+ |Mini-Circuits ZFRSC-123-S+ (Splitter) | +--------------------------------------------+ |Keysight N9040B (SA) | +--------------------------------------------+ ## Changelog ### 3-27-2026, 2:42 MT - Added Mini-Circuits ZFRSC-123-S+ splitter to do dual monitor with two spectrum analyzers, nominal insertion loss is ~9.6 dB in the operating frequency.