High Frequency Observer's Checklist
|
1 Choose observing strategy
- Are your sources strong (at least 0.1 Jy, preferably
stronger)? Then you can apply self-calibration to the source, and it
is sufficient to observe the calibrator every 30 minutes at 22 and 43
GHz.
- Are your sources weak? Apply either the
fast-switching technique
or, if your source contains a maser you can use the maser for
self-calibration (see the section on
phase stability).
- For examples on observing strategies, check some
sample observe files.
|
2 Select calibrators
- Primary flux calibrators: Try to observe 3C286 (or 3C48 as a
secondary choice) to achieve absolute gain calibration. Note
however, that especially in A- and B-array you will need to use
clean component models since both 3C286 and 3C48 are resolved at
high frequencies, see
absolute gain
calibration.
- Normal calibrators: from the
List of
VLA Calibrators,
select compact calibrators that lie as close as possible to your
target source. A flux density of around 0.5 Jy is recommended at
full bandwidth, and preferably stronger at narrower
bandwidths.
- Fast Switching calibrators: These calibrators need to be at
least 0.3 Jy, and to have a maximum distance from your target
source of around 3 degrees.
- Bandpass calibrators: if you are observing spectral lines,
ensure you have also a stronger (a few Jy if possible)
calibrator in order to perform bandpass calibration.
- Suitable pointing sources:
referenced pointing scans
have to be done at sources which are at least 0.5 Jy, and should
be as close as possible to the target.
|
3 Determine observing setup
- Continuum mode: use available NRAO standard setups but consider
- Time
averaging: make sure you have short enough integration time
in order to reduce time averaging losses.
- Spectral line modes
see table.
- Velocity resolution: make sure the spectral resolution is
enough to resolve your line.
- Hanning smoothing on line is possible, with a cost of a
factor of 2 in spectral resolution.
- Make sure you have enough line free bandwidth to measure
the continuum flux.
- Time
averaging: make sure you have short enough integration
time in order to reduce time averaging losses.
- Integration time: the
minimum possible
integration time depends on the total number of channels
produced in the correlator.
|
|
4 Prepare the schedule file
|
5 Check your schedule:
- General:
- Are your sources up? Check in the SummaryReport.
- Have you included
referenced pointing
scans at X-band?
- Is the integration time for those scans 10 seconds
(specified on the DS card)?
- Is the total dwell time for the pointing scans at least
2.5 minutes?
- Are the pointing corrections applied to the correct scans?
Specified with a T in the source card. NB, the T should
not be specified in the pointing scan itself.
- Is the schedule in LST stop times?
- Are your source coordinates entered correctly and in the
same epoch (J2000 or B1950)?
- Have you integrated long enough to achieve your desired
sensitivity?
Continuum:
- Are your AC and BD IFs at different frequencies?
- Is your integration time short enough to reduce time
averaging losses?
Spectral line:
- Did you check that the
correlator mode
is correct on the DS card?
- Are the rest frequencies of your lines correct, and in MHz?
Seen on the FI card.
- Is the velocity definition correctly specified? On the FI
card this should be V=radio (most often for Galactic work) or
Z=optical (mainly used for extra-galactic observing).
- Is the centre of the line in the centre of the band?
Specified with a T on the FI card.
- Is the rest frame correctly specified on the FI card?
Barycentric (B) or LSR (L).
Fast switching:
- Did you check that the slew time between your sources is
shorter than the cycle time? In normal mode (not fast
switching mode) the slew time is the move time minus
20sec.
- Is the integration time as short as possible? 3 seconds is
recommended, although this is subject to the
minimum possible integration time
|
|
6 Submit your schedule
|