VLA calibrator information for 0632+1022

This page summarizes the information for 0632+1022 as found in the original VLA calibrator list and, if found there, a link to search the NRAO VLA Archive Survey (NVAS) for calibrator data before 2010. Furthermore, a table with the most recent approximate flux densities, starting from 2017 as mined from the VLA CASA pipeline is presented.

If shown at the top, we have recovered the original, pre-WIDAR ANTSOL flux density solutions from the period roughly 2000-2007; symbols as explained next.
The mined data are plotted (gray, on the left hand side) as function of (log) frequency on the top and as function of time on the bottom. The frequency band symbols in the bottom panel follow the symbols as outlined in the top panel:

4-band  (~75 MHz) horizontal stripe       X-band (~10.0 GHz) cross
P-band (~350 MHz) open triangle        U/Ku-band (~15.0 GHz) filled square
L-band (~1.5 GHz) VLA-Y shape             K-band (~22.2 GHz) open circle
S-band (~3.0 GHz) filled triangle      A/Ka-band (~33.2 GHz) 6-pointed star
C-band (~6.0 GHz) open square             Q-band (~45.0 GHz) filled circle
Assume a 10% flux density error on each point, up to 30% for the higher frequency data points. The dashed lines in the frequency plot indicate the approximate spectral index in the frequency band (tied to the measured flux density).
Depending on the spectral behavior, different receiver observing bands (as indicated with the log-frequency axis) may have very different typical flux densities. Note that there can be significant flux density changes for different array configurations, which start date is indicated at the top of the time-line figure. Calendar years are separated by vertical dotted lines.
If shown, a curve depicts a fit to the (unweighted) average data for each band (if there are more than two bands with measured flux densities). The fit equation is listed at the top where the x-coordinate represents the base-10 log of the frequency (GHz) and the y-coordinate represents the base-10 log of the flux density (mJy/bm). The fit may use more data than shown and is using data with different time stamps, which means typically different flux densitities in a single band for genuine variable sources (and/or observed in different array configurations).
Depending on the variability of the source, array configuration and the quality of the data, this fit may, or may not, be representative for the data!

(Click on the figure for a larger view in a new tab/window)

Original (outdated) VLA calibrator list information:
 IAU NAME EQUINOX  PC RA(hh,mm,ss)    DEC(ddd,mm,ss)   POS.REF ALT.NAME
 ===================================================================
 0632+103   J2000  C 06h32m15.3269s    10d22'01.676"     Nov96
 0629+104   B1950  C 06h29m29.4510s    10d24'16.239"
 -----------------------------------------------------
 BAND        A B C D    FLUX(Jy)    UVMIN(kL)  UVMAX(kL)
 =====================================================
  20cm    L  P P P P       2.45
   6cm    C  P P P P       0.90                      500
 3.7cm    X  S S S S       0.50                      500
   2cm    U  X X X X       0.20
 0.7cm    Q  X X X X       0.08

Default NVAS search around this position (in new tab/window)

Results from CASA pipeline flux density mining:
Observing date (UT)Flux density (Jy/bm)Source name used
L-band data ("VLA Y-arm" symbols)
201707292.280J0632+1022
201708192.258J0632+1022
201708252.173J0632+1022
201708252.287J0632+1022
201709172.288J0632+1022
201710232.255J0632+1022
201712082.279J0632+1022
201712272.295J0632+1022
201801152.331J0632+1022
201910012.315J0632+1022
202204152.357J0632+1022
202301122.395J0632+1022
S-band data (filled triangles)
201707291.306J0632+1022
201708191.280J0632+1022
201708251.276J0632+1022
201708251.278J0632+1022
201709171.306J0632+1022
201710231.262J0632+1022
201712081.294J0632+1022
201712271.316J0632+1022
201801151.339J0632+1022
C-band data (open squares)
201705300.680J0632+1022
201708110.631J0632+1022
201804020.390J0632+1022
201804030.386J0632+1022